BFI-Elektronik   BFI-Elektronik
Device functions

.

Regulated High voltage power supplies

 

 

Logic outputs

The device contains two potential-free outputs K1 (clamps 24, 21, 22) and K2 (clamps 14, 11, 12) which are used to report the system state. The standard device uses two relays to communicate with a SPC or an indicator. A buzzer may also be connected to this outputs.
The relay outputs are change-over contacts for an AC voltage up to 230V and a current up to 5A.

The outputs of the standard device indicate following device states:

  • Output K1 is closed if the output voltage is greater than 7kV.
  • Output K2 is closed if the device is switched off because of constant short circuit shutdown.
Options to adapt the device to customer specifications:
  • Output K1 may be configured to drive an usual LED. In this case the internal 5V-suplly voltage will be carried over a resistor to the clamps 21 and 24. The maximum current to drive the LED is 10mA.
  • The conditions which cause output switching may be free chosen.