Logic outputs
The outputs of the standard device indicate following device states:
- Output K1 is closed if the output voltage is greater than 7kV.
- Output K2 is closed if the device is switched off because of constant short circuit shutdown.
Options to adapt the device to customer specifications:
- Output K1 may be configured to drive an usual LED. In this case the internal 5V-suplly voltage will be carried over a resistor to the clamps 21 and 24. The maximum current to drive the LED is 10mA.
- The conditions which cause output switching may be free chosen.
|